NON-DESTRUCTIVE EVALUATION OF CORROSION RATEObjective: 1. Non Destructive Evaluation of corrosion rate in bare rebar using peizo sensors via EMI technique Apparatus Used: 1. A Empty Tank 2. Brine Solution 3. Copper Rod as Cathode 4. Bare Rebar as Anode 5. PZT Patch 6. Volt Meter 7. Bare Rebar Holder 8. Copper Rod Holder ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]()
Step-1: (a) Click on Add Button to bring Empty Tank.
Step-1: (b) Click on Tank to Place it on the position.
Step-1: (c) Click on Add Button to bring Brine Solution.
Step-1: (d) Click on Brine Solution to pour it into the Tank.
Step-1: (e) Click on Add Button to bring Bare Rebar Holder.
Step-1: (f) Click on Add Button to bring Bare Rebar.
Step-1: (g) Click on Bare Rebar to fix it on the Bare Rebar Holder.
Step-1: (h) Click on Add Button to bring Copper Rod Holder.
Step-1: (i) Click on Add Button to bring Copper Rod.
Step-1: (j) Click on Copper Rod to fix it on the Copper Rod Holder.
Step-1: (k) Now click on Next Button.
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]()
Step-2: (a) Click on Black Clip to attach wire with Copper Rod.
Step-2: (b) Click on Red Clip to attach wire with Bare Rebar.
Step-2: (c) Switch on the power button of Volt Meter.
Step-2: (d) Now click on Next Button.
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() Pristine Specimen ![]() Corroded Specimen Select option for downloading the readings |